005 . STPBHF-I059(355) , JEFFERSON

COUNTY: JEFFERSON

SHALL BE COMPLETED BY: May 1, 2014

for constructing the I-20/59 Lighting (Phase 1A) from 3700 feet east of the Eastbound Stephens Expressway Interchange to 2000 feet east of the I-20/59 split in Birmingham. Length 3.522 mi.

The Bracket Ranges shown herein are to provide general financial information to Contractors and Bonding Companies concerning a Project's complexity and size only. THESE BRACKETS SHOULD NOT BE USED IN PREPARING A BID, NOR WILL THESE BRACKETS HAVE ANY BEARING ON THE DECISION TO AWARD ANY CONTRACT.

BRACKET ESTIMATE: $3,890,958 TO $4,755,616


THE PRINCIPAL ITEMS OF WORK ARE APPROXIMATELY AS FOLLOWS:

ITEM CODE QUANTITY UNIT ITEM DESCRIPTION
201A002 1 LS Clear & Grub (Maximum Allowable Bid $ 4000.00 Per Acre)(Approximately 1 acre)
600A000 1 LS Mobilization
610D003 278 SQYD Filter Blanket Geotextile
665A000 1 ACRE Temporary Seeding
665B001 3 TON Temporary Mulching
665G000 100 EACH Sand Bags
665J002 7000 LF Silt Fence
665N000 40 TON Temporary Coarse Aggregate ALDOT No 1
665O001 7000 LF Silt Fence Removal
665Q002 500 LF Wattle
680A001 1 LS Geometric Controls
698A000 1 LS Construction Fuel (Maximum Bid Limited 245,000.00)
740B000 2510 SQFT Construction Signs
740C000 33 SQFT Special Construction Signs
740D000 275 EACH Channelizing Drums
740F002 4 EACH Barricades, Type III
740I002 2 EACH Warning Lights, Type B
741C010 2 EACH Port Seq Arrow & Chevron Sign Unit
742A001 6 EACH Portable Changeable Message Sign Type 2
750B437 102 EACH Rdwy Lum Ass W/1 Mod Cob 250W Lum
750B438 199 EACH Rdwy Lum Assem w/ 1,Mod Cob Hd, 400 W
750B443 19 EACH Rdwy Lum Assm,2 mod Cobra,400W
750B500 27 EACH Rdwy Lum Assem w/ 1,Seg Refl U Pen,150 W
750C010 285 EACH Pole Foundation,Roadway
750D200 70 EACH Electrical Junction Box,Type 1
750E123 3785 LF Conduit, 3/4", Rigid Metallic
750E125 4650 LF Conduit,1 1/4",Rigid Metallic
750E126 3800 LF Conduit, 1 1/2 ", Rigid Metallic
750F022 11750 LF Conductor, #10 AWG
750F024 17322 LF Conductor, #6 AWG
750F025 8000 LF Conductor, #4 AWG
750F026 1400 LF Conductor, #2 AWG
750G010 30600 LF Combined Duct & Cable 2#6AWG/1#6AWG GND
750G011 16565 LF Combined Duct & Cable 2#4AWG/1#6 AWG GND
750G012 1840 LF Combined Duct & Cable,4#6AWG/1 #6AWG GND
750G014 295 LF Combined Duct & Cable, 6#6AWG/1#6AWG GND
750G022 305 LF Combined Duct & Cable, 4#4AWG/1#6AWG GND
750G030 10350 LF Comb Duct & Cable,2 #2 AWG/1 #6 AWG GND
750G032 1915 LF Combined Duct & Cable, 4#2AWG/1#6AWG GND
750H005 4 EACH Service Pole
750I005 4 EACH Lighting Control Center
751J006 212 EACH Remove Luminaire Pole Found. Concrete
751L002 4 EACH Remove Lighting Control Cent, 6 Circuit
751L015 4 EACH Remove Service Pole
751L025 247 EACH Remove Roadway Luminaire Assembly
751M000 1 LS Remove Conductors
751M002 1 LS Remove Conductors and Conduits
756A022 2920 LF 4" Elect Conduit 1 Line Ty 5 Install
756A028 470 LF 6" Elect Conduit 1 Line Ty 5 Install