COUNTY: MONTGOMERY
WORKING DAYS: 150
MBE/DBE CONTRACT OBLIGATION: 5 %
for constructing the Planing, Resurfacing, Traffic Stripe, and Fiber Optic and Signals on W.L. Dickinson Drive from CSX Railroad to 0.23 miles south of SR-9 (US-231) including Industrial Access Improvements at Maxwell AFB (Gunter Annex) Cyber Commander. Length 1.886 mi.The Bracket Ranges shown herein are to provide general financial information to Contractors and Bonding Companies concerning a Project's complexity and size only. THESE BRACKETS SHOULD NOT BE USED IN PREPARING A BID, NOR WILL THESE BRACKETS HAVE ANY BEARING ON THE DECISION TO AWARD ANY CONTRACT.
BRACKET ESTIMATE: $2,484,723 TO $3,036,884
| ITEM CODE | QUANTITY | UNIT | ITEM DESCRIPTION | |
|---|---|---|---|---|
| 201A002 | 1 | LS | Clear & Grub (Maximum Allowable Bid $ 4000.00 Per Acre)(Approximately 5 Acres) | |
| 206C017 | 15 | SQYD | Removing Concrete Pad | |
| 206D000 | 323 | LF | Removing Pipe | |
| 206D001 | 974 | LF | Removing Guardrail | |
| 206D002 | 86 | LF | Removing Curb | |
| 206E001 | 16 | EACH | Removing Inlets | |
| 206E008 | 4 | EACH | Removing Guardrail End Anchor (All Type) | |
| 210A000 | 2313 | CUYD | Unclassified Excavation | |
| 210D021 | 615 | CUYD | Borrow Excav (Lse Trb Meas)(A-4 Better) | |
| 214A000 | 2324 | CUYD | Structure Excavation | |
| 214B001 | 996 | CUYD | Foundation Backfill Commercial | |
| 401A004 | 62901 | SQYD | Bituminous Treatment E | |
| 405A000 | 5225 | GAL | Tack Coat | |
| 407B000 | 11 | MILE | Joint Sealant For Hot Mix Asphalt Pave | |
| 408A052 | 62901 | SQYD | Plane Pvmt Appr 1.10" - 2.0" | |
| 410C000 | 1 | EACH | Contractor Retained Profilograph | |
| 424A361 | 6348 | TON | Superpave Wrg Surf 3/4" ESAL C/D | |
| 424A364 | 425 | TON | Superpave Wrg Surf Pat 3/4" ESAL C/D | |
| 424A367 | 249 | TON | Superpave Wrg Surf Lev 3/4"ESAL C/D | |
| 424B650 | 7224 | TON | Superpave Upr Bndr Lay 3/4" Esal C/D | |
| 424B681 | 99 | TON | Superpave Low Bndr Lay 1" Esal C/D | |
| 424C360 | 143 | TON | Superpave Base Layer 1" ESAL C/D | |
| 430B014 | 980 | TON | Agg Surf (ALDOT #410 Modified) | |
| 530A001 | 3247 | LF | 18" Roadway Pipe (Class 3 R.C.) | |
| 530A002 | 447 | LF | 24" Roadway Pipe (Class 3 R.C.) | |
| 530A099 | 12 | LF | 12" Roadway Pipe (Class 3 R.C.) (Ext) | |
| 530A100 | 4 | LF | 15" Roadway Pipe (Class 3 R.C.) (Ext) | |
| 530A106 | 8 | LF | 48" Roadway Pipe (Class 3 R.C.) (Ext) | |
| 530B001 | 55 | LF | 22"x14" Roadway Pipe Class 3 R.C. | |
| 534E001 | 3014 | LF | Clean Exist Pipe Less Than Or 48" | |
| 535A085 | 60 | LF | 24" Side Drain Pipe (Class 3 R.C.) | |
| 535B088 | 84 | LF | 22" x 14" Side Drain Pipe (Cl 3 R.C.) | |
| 600A000 | 1 | LS | Mobilization | |
| 610D003 | 1335 | SQYD | Filter Blanket Geotextile | |
| 614A000 | 135 | CUYD | Slope Paving | |
| 619A002 | 2 | EACH | 18" Road Pipe End Treatment Cl 1 | |
| 619A102 | 2 | EACH | 24" Side Drain Pipe End Treat Cl 1 | |
| 619B116 | 6 | EACH | 22"x14" Side Drain End Treat Cl 1 | |
| 620A000 | 20 | CUYD | Minor Structure Concrete | |
| 621A011 | 5 | EACH | Junction Boxes, Type 1 Or 1P | |
| 621A019 | 1 | EACH | Junction Boxes, Type 1 Or 2P | |
| 621B011 | 1 | EACH | Junction Box Units, Type 1 Or 1P | |
| 621B014 | 1 | EACH | Junction Box Units, Type 1 Or 2P | |
| 621C008 | 2 | EACH | Inlets, Type E | |
| 621C020 | 14 | EACH | Inlets, Type Y | |
| 621C100 | 5 | EACH | Inlets, Type PR | |
| 621D019 | 16 | EACH | Inlet Units, Type Y | |
| 621F030 | 1 | EACH | Manhole Height Adjustment | |
| 623B000 | 1448 | LF | Concrete Curb, Type N | |
| 623B001 | 71 | LF | Concrete Curb, Type N Special | |
| 623C003 | 119 | LF | Combination Curb & Gutter, Type C (Mod) | |
| 630A001 | 638 | LF | Steel Beam Guardrail, Cl A, Ty 2 | |
| 630C000 | 2 | EACH | Guardrail End Anchor, Type 10 | |
| 630C001 | 2 | EACH | Guardrail End Anchor, Type 8 | |
| 650A000 | 2269 | CUYD | Topsoil | |
| 652A100 | 5 | ACRE | Seeding | |
| 654A001 | 526 | SQYD | Solid Sodding (Bermuda) | |
| 656A010 | 5 | ACRE | Mulching | |
| 665A000 | 5 | ACRE | Temporary Seeding | |
| 665B001 | 15 | TON | Temporary Mulching | |
| 665G000 | 165 | EACH | Sand Bags | |
| 665J002 | 2387 | LF | Silt Fence | |
| 665N000 | 200 | TON | Temporary Coarse Aggregate ALDOT No 1 | |
| 665O001 | 2387 | LF | Silt Fence Removal | |
| 665P005 | 27 | EACH | Inlet Protection, Stage 3 Or 4 | |
| 665Q002 | 1780 | LF | Wattle | |
| 680A001 | 1 | LS | Geometric Controls | |
| 698A000 | 1 | LS | Construction Fuel (Maximum Bid Limited 132,000.00) | |
| 701A231 | 5 | MILE | Solid White Cl 2 Ty A Traf Str | |
| 701A235 | 5 | MILE | Solid Yellow Cl 2 Ty A Traf Str | |
| 701A240 | 5 | MILE | Broken White Cl 2 Ty A Traf Str | |
| 701B063 | 600 | LF | Dotted Cl 2 Ty A Traf Str LD 10" W | |
| 701B205 | 2875 | LF | Dotted Cl 2 Ty A Traf Str | |
| 701C000 | 9 | MILE | Broken Temporary Traffic Stripe | |
| 701C001 | 16 | MILE | Solid Temporary Traffic Stripe | |
| 703A002 | 2570 | SQFT | Traffic Control Marking, Class 2, Type A | |
| 703B002 | 124 | SQFT | Traffic Control Legends, Class 2, Type A | |
| 703D001 | 528 | SQFT | Temporary Traffic Control Markings | |
| 705A030 | 240 | EACH | Pavement Markers, Class A-H, Type 2-C | |
| 705A031 | 262 | EACH | Pavement Markers, Class A-H, Type 1-A | |
| 705A038 | 110 | EACH | Pavement Markers, Class A-H, Type 2-E | |
| 707B003 | 2 | EACH | Type A Hazard Marker Installation | |
| 710A115 | 92 | SQFT | Cl 4 Alum Sign 0.08"/St 14 Ga Ty III/ IV | |
| 710A126 | 100 | SQFT | Cl 8 Alum Sign 0.08"/St 14 Ga Ty IX Bg | |
| 710B021 | 741 | LF | Rdwy Sign Pt(#3 UCh GS or 2"14Ga SqTuSt) | |
| 730A000 | 1 | LS | Removal Of Exist Traffic Control Unit Dickinson Drive at Gunter Park Drive) | |
| 730A001 | 1 | LS | Removal Of Exist Traffic Control Unit Dickinson Drive at Turner Blvd) | |
| 730C000 | 1 | LS | Furnish and Install Traffic Control Unit Dickinson Drive at Gunter Park Drive) | |
| 730C001 | 1 | LS | Furnish and Install Traffic Control Unit Dickinson Drive at Turner Blvd) | |
| 730E000 | 6 | EACH | Metal Traffic Signal Pole Foundation | |
| 730F000 | 1 | EACH | Met Tr Signal Pole W/_Mast Arm Assembly 40 ft. | |
| 730F001 | 2 | EACH | Met Tr Signal Pole W/_Mast Arm Assembly 45 ft. | |
| 730F002 | 3 | EACH | Met Tr Signal Pole W/_Mast Arm Assembly 50 ft. | |
| 730K000 | 6 | EACH | Traffic Signal Junction Box | |
| 730L002 | 40 | LF | 1", Metallic, Conduit | |
| 730L003 | 60 | LF | 1", Non-Metallic, Conduit | |
| 730L005 | 1450 | LF | 2", Non-Metallic, Conduit | |
| 730N010 | 6 | EACH | Luminaire Extension Assembly, 12 ft. | |
| 730P022 | 10 | EACH | Vehicular Signal Head, 12 Inch, 3 Sect | |
| 730P024 | 2 | EACH | Vehicular Signal Head, 12 Inch, 5 Sect | |
| 730R022 | 2 | EACH | Controller Assembly, Type III, 8 Phase | |
| 730T000 | 2 | EACH | Wood Pole | |
| 730U015 | 1 | LS | Video Detection System | |
| 730U016 | 1 | LS | Video Detection System | |
| 734A012 | 15150 | LF | Cable OSP, Loose Tube, 36F SM | |
| 734A100 | 11630 | LF | Messenger Wire | |
| 734B007 | 450 | LF | Drop Cable OSP 12F SM Central Core | |
| 734E100 | 70 | LF | Buried Duct HDPE SDR11 2 x 2 Inch | |
| 734F002 | 2 | EACH | Distribution Hardware SFDU 12 Fiber | |
| 734G001 | 24 | EACH | Connector ST Termination SM | |
| 734G005 | 4 | EACH | Splice Closure, Aerial With Trays | |
| 734G009 | 24 | EACH | Splicing, Fusion | |
| 734H041 | 4 | EACH | Patch Cord Duplex SM,ST to LC 2 Meter | |
| 734H070 | 2 | EACH | Fanout Kit, SM | |
| 734J000 | 2 | EACH | Commbox F1 | |
| 734M000 | 2 | EACH | Riser Assembly | |
| 734N052 | 2 | EACH | Ethernet Gigabit Network Switch | |
| 734N100 | 4 | EACH | Cat 5E Patch Cords,3 Meter | |
| 734N900 | 2 | EACH | Video Encoder | |
| 734S000 | 14 | EACH | Fiber Storage Rack (Aerial) | |
| 734T110 | 1 | LS | Testing, Fiber Optic Systems | |
| 738A000 | 2 | EACH | CCTV Camera, PTZ | |
| 738T110 | 1 | LS | Testing, CCTV | |
| 740B000 | 1129 | SQFT | Construction Signs | |
| 740D000 | 270 | EACH | Channelizing Drums | |
| 740E000 | 180 | EACH | Cones (36" High) | |
| 740F002 | 22 | EACH | Barricades, Type III | |
| 740I002 | 11 | EACH | Warning Lights, Type B | |
| 740M001 | 180 | EACH | Ballast For Cone | |
| 741C010 | 3 | EACH | Port Seq Arrow & Chevron Sign Unit | |
| 745A000 | 200 | HOUR | Uniformed Police Officer | |
| 756A028 | 445 | LF | 6" Elect Conduit 1 Line Ty 5 Install |