COUNTY: CALHOUN
WORKING DAYS: 305
MBE/DBE CONTRACT OBLIGATION: 10 %
for constructing the Grade, Drain, Base, Pave, Bridge Culverts, Signing and Signals on SR-901 (Anniston E. Bypass) from 1500' south of Lake Yahou to SR-1 (US-431) in Anniston. Length 3.731 mi.The Bracket Ranges shown herein are to provide general financial information to Contractors and Bonding Companies concerning a Project's complexity and size only. THESE BRACKETS SHOULD NOT BE USED IN PREPARING A BID, NOR WILL THESE BRACKETS HAVE ANY BEARING ON THE DECISION TO AWARD ANY CONTRACT.
BRACKET ESTIMATE: $12,554,822 TO $15,344,782
| ITEM CODE | QUANTITY | UNIT | ITEM DESCRIPTION | |
|---|---|---|---|---|
| 201A002 | 1 | LS | Clear & Grub (Maximum Allowable Bid $ 4000.00 per Acre)(Approx. 10 Acres) | |
| 206B000 | 1 | LS | Removal Of Old Box Culvert Station STA 40+50 | |
| 206B001 | 1 | LS | Removal Of Old Box Culvert Station STA 407+50 | |
| 206B002 | 1 | LS | Removal Of Old Box Culvert Station STA 406+50 | |
| 206B003 | 1 | LS | Removal Of Old Box Culvert Station STA 13+60 | |
| 206C010 | 881 | SQYD | Removing Concrete Driveway | |
| 206C023 | 160 | SQYD | Removing Riprap | |
| 206D000 | 1114 | LF | Removing Pipe | |
| 206D001 | 253 | LF | Removing Guardrail | |
| 206E000 | 12 | EACH | Removing Headwalls | |
| 206E001 | 6 | EACH | Removing Inlets | |
| 206E008 | 2 | EACH | Removing Guardrail End Anchor (All Type) | |
| 210A000 | 86369 | CUYD | Unclassified Excavation | |
| 214A000 | 6645 | CUYD | Structure Excavation | |
| 214B001 | 844 | CUYD | Foundation Backfill Commercial | |
| 231B001 | 4799 | TON | Roadbed Stabilizing Material ALDOT #467 | |
| 231C000 | 399 | RBST | Stabilizing Roadbed With In-Place Mat | |
| 301A003 | 50807 | SQYD | CABC Type B Plant Mix 3.75" Thick | |
| 301A004 | 52956 | SQYD | CABC Type B Plant Mix 4" Thick | |
| 301A006 | 268 | SQYD | CABC Type B Plant Mix 4.5" Thick | |
| 301A012 | 215434 | SQYD | CABC Type B Plant Mix 6" Thick | |
| 401A000 | 218731 | SQYD | Bituminous Treatment A | |
| 401B100 | 2488 | SQYD | Bituminous Treatment E (W/Polymer) | |
| 405A000 | 30422 | GAL | Tack Coat | |
| 407B000 | 12 | MILE | Joint Sealant For Hot Mix Asphalt Pave | |
| 408A052 | 21519 | SQYD | Plane Pvmt Appr 1.10" - 2.0" | |
| 408A053 | 2488 | SQYD | Plane Pvmt Appr 2.1" - 3.0" | |
| 410C000 | 1 | EACH | Contractor Retained Profilograph | |
| 410H000 | 1 | EACH | Material Remixing Device | |
| 410I000 | 1 | EACH | Smoothness Testing Certified Inertial Pr | |
| 424A280 | 10383 | TON | Superpave Wrg Surf 1/2" ESAL E | |
| 424A286 | 150 | TON | Superpave Wrg Surf Level 1/2" ESAL E | |
| 424A360 | 8960 | TON | Superpave Wrg Surf 1/2" ESAL C/D | |
| 424A366 | 200 | TON | Superpave Wrg Surf Lev 1/2" ESAL C/D | |
| 424B280 | 13475 | TON | Superpave Upr Bndr 3/4" ESAL E | |
| 424B581 | 45696 | TON | Superpave Lwr Bndr 1" ESAL E | |
| 424B585 | 50 | TON | Superpave Lwr Bndr Patch 1" ESAL E | |
| 424B588 | 200 | TON | Superpave Lwr Bndr Level 3/4" ESAL E | |
| 424B650 | 11884 | TON | Superpave Upr Bndr Lay 3/4" Esal C/D | |
| 424B681 | 11349 | TON | Superpave Low Bndr Lay 1" Esal C/D | |
| 424B685 | 50 | TON | Superpave Low Bndr Patch 1" Esal C/D | |
| 428C000 | 79610 | LF | Scoring Bit Pvmt Surface By Cutting | |
| 430B002 | 200 | TON | Agg Surf (ALDOT #467) | |
| 430B043 | 200 | TON | Agg Surf (1" Down, Crusher Run) | |
| 450B000 | 320 | SQYD | Reinforced Concrete Bridge End Slab | |
| 502A000 | 265936 | LB | Steel Reinforcement | |
| 524A010 | 1534 | CUYD | Culvert Concrete | |
| 530A002 | 240 | LF | 24" Roadway Pipe (Class 3 R.C.) | |
| 530A004 | 20 | LF | 36" Roadway Pipe (Class 3 R.C.) | |
| 530A013 | 300 | LF | 24" Roadway Pipe (Class 4 R.C.) | |
| 530A104 | 8 | LF | 36" Roadway Pipe (Class 3 R.C.) (Ext) | |
| 530A151 | 18 | LF | 15" Roadway Pipe (14 Gauge C.C.S.) | |
| 530A494 | 200 | LF | 18" Roadway Pipe(14 Gauge C.M.)(Temp) | |
| 530B000 | 8 | LF | 18"x11" Roadway Pipe Class 3 R.C. | |
| 533A098 | 56 | LF | 18" Storm Sewer Pipe (Class 3 R.C.) | |
| 535A001 | 412 | LF | 18" Side Drain Pipe | |
| 600A000 | 1 | LS | Mobilization | |
| 610C001 | 3794 | TON | Loose Riprap Class 2 | |
| 610D003 | 3425 | SQYD | Filter Blanket Geotextile | |
| 614A000 | 52 | CUYD | Slope Paving | |
| 618B003 | 494 | SQYD | Concrete Driveway 6" Thick Wire Mesh | |
| 619A002 | 4 | EACH | 18" Road Pipe End Treatment Cl 1 | |
| 619A003 | 5 | EACH | 24" Road Pipe End Treatment Cl 1 | |
| 619A005 | 1 | EACH | 36" Road Pipe End Treatment Cl 1 | |
| 619A101 | 20 | EACH | 18" Side Drain Pipe End Treat Cl 1 | |
| 620A000 | 3 | CUYD | Minor Structure Concrete | |
| 621A002 | 1 | EACH | Junction Boxes, Type 4 Or 2P | |
| 621A019 | 1 | EACH | Junction Boxes, Type 1 Or 2P | |
| 621A034 | 1 | EACH | Junction Boxes, Type 4 (Modified) | |
| 621B014 | 1 | EACH | Junction Box Units, Type 1 Or 2P | |
| 621C002 | 1 | EACH | Inlets, Type C, P1 Or P3 | |
| 621C019 | 1 | EACH | Inlets, Type X | |
| 621C020 | 4 | EACH | Inlets, Type Y | |
| 621D019 | 3 | EACH | Inlet Units, Type Y | |
| 629A035 | 276 | LF | Conc Med Or Safety Barr, Ty 8 | |
| 630A001 | 4345 | LF | Steel Beam Guardrail, Cl A, Ty 2 | |
| 630A034 | 425 | LF | St Bm Gdrl Cl A Ty 2 8'-0" Post | |
| 630C000 | 10 | EACH | Guardrail End Anchor, Type 10 | |
| 630C001 | 1 | EACH | Guardrail End Anchor, Type 8 | |
| 630C003 | 4 | EACH | Guardrail End Anchor, Type 13 | |
| 630C050 | 1 | EACH | Guardrail End Anchor, Type 20 Series | |
| 634A002 | 1409 | LF | Industrial Fence, 6 Feet High | |
| 634D004 | 1 | EACH | Gate, 14' Wide, W/Fit W/O Barb Wire | |
| 634D007 | 1 | EACH | Gate, 20' Wide, W/Fit W/O Barb Wire | |
| 641A612 | 405 | LF | 6 Inch Ductile Iron Water Main Laid | |
| 641A682 | 85 | LF | 6 Inch Ductile Iron Water Main Laid RJ | |
| 641C500 | 530 | LB | Ductile Iron Fittings | |
| 641J516 | 2 | EACH | 6 Inch Gate Valve With Box | |
| 641L500 | 3 | CUYD | Concrete for Water Mains (Thrust Blocks) | |
| 641P601 | 2 | EACH | Connection to Existing Water System | |
| 649A535 | 85 | LF | 12 Inch Stl Encase Pipe Ty 1 Install | |
| 650B000 | 7488 | CUYD | Topsoil From Stockpiles | |
| 652A100 | 6 | ACRE | Seeding | |
| 652C000 | 44 | ACRE | Mowing | |
| 654A001 | 1888 | SQYD | Solid Sodding (Bermuda) | |
| 656A010 | 6 | ACRE | Mulching | |
| 659C002 | 2608 | SQYD | Erosion Control Product, Type S2 | |
| 665A000 | 5 | ACRE | Temporary Seeding | |
| 665B001 | 15 | TON | Temporary Mulching | |
| 665C010 | 500 | LF | Temporary Pipe | |
| 665D001 | 10 | EACH | Temporary Pipe End Treatment | |
| 665E000 | 300 | SQYD | Polyethylene | |
| 665G000 | 1000 | EACH | Sand Bags | |
| 665I000 | 83 | TON | Temporary Riprap, Class 2 | |
| 665J002 | 2586 | LF | Silt Fence | |
| 665K000 | 1000 | CUYD | Drainage Sump Excavation | |
| 665N000 | 183 | TON | Temporary Coarse Aggregate ALDOT No 1 | |
| 665O001 | 2586 | LF | Silt Fence Removal | |
| 665P005 | 7 | EACH | Inlet Protection, Stage 3 Or 4 | |
| 665Q002 | 2200 | LF | Wattle | |
| 665T000 | 54 | LF | Temporary Earth Berms | |
| 665V001 | 100 | LB | Flocculant Powder | |
| 665W001 | 25 | EACH | Flocculant Block | |
| 666A001 | 9 | ACRE | Pest Control Treatment | |
| 680A001 | 1 | LS | Geometric Controls | |
| 698A000 | 1 | LS | Construction Fuel (Maximum Bid Limited 635,000.00) | |
| 701A227 | 12 | MILE | Solid White Cl 2 Ty A Traf Str 5" W | |
| 701A230 | 11 | MILE | Solid Yellow Cl 2 Ty A Traf Str 5" W | |
| 701A239 | 11 | MILE | Broken White Cl 2 Ty A Traf Str 5" W | |
| 701B059 | 1060 | LF | Dotted Cl W Ty A Traf Str LD 10" W | |
| 701B063 | 750 | LF | Dotted Cl 2 Ty A Traf Str LD 10" W | |
| 701B075 | 1060 | LF | Dotted Cl W Ty B Traf Str Black LD 10" W | |
| 701B207 | 5650 | LF | Dotted Cl 2 Ty A Traf Str 5" W | |
| 701C001 | 12 | MILE | Solid Temporary Traffic Stripe | |
| 701C006 | 5 | MILE | Solid Temporary Traffic Stripe Rem Tape | |
| 701D005 | 12 | MILE | Solid Traffic Stripe Removed | |
| 701G142 | 1060 | LF | Broken White Cl W Ty A Traf Str 5" W | |
| 701G146 | 1060 | LF | Solid White Cl W Ty A Traf Str 5" W | |
| 701G154 | 1060 | LF | Solid Yellow Cl W Ty A Traf Str 5" W | |
| 701G161 | 1060 | LF | Broken Black Cl W Ty B Traf Str 5"W | |
| 703A002 | 8300 | SQFT | Traffic Control Marking, Class 2, Type A | |
| 703A011 | 40 | SQFT | Traffic Control Markings, Class W, Ty A | |
| 703B002 | 800 | SQFT | Traffic Control Legends, Class 2, Type A | |
| 703B011 | 50 | SQFT | Traffic Control Legends Cl W Ty A | |
| 705A011 | 1500 | EACH | Pavement Markers, Class C, Type 1-A | |
| 705A012 | 1500 | EACH | Pvmtment Markers, Class C, Type 1-B | |
| 705A023 | 75 | EACH | Pavement Markers, Class C, Type 2-D | |
| 705A030 | 475 | EACH | Pavement Markers, Class A-H, Type 2-C | |
| 705A031 | 975 | EACH | Pavement Markers, Class A-H, Type 1-A | |
| 705A032 | 300 | EACH | Pavement Markers, Class A-H, Type 1-B | |
| 705A037 | 75 | EACH | Pavement Markers, Class A-H, Type 2-D | |
| 705A038 | 250 | EACH | Pavement Markers, Class A-H, Type 2-E | |
| 710A115 | 784 | SQFT | Cl 4 Alum Sign 0.08"/St 14 Ga Ty III/ IV | |
| 710A126 | 101 | SQFT | Cl 8 Alum Sign 0.08"/St 14 Ga Ty IX Bg | |
| 710A140 | 484 | SQFT | Cl 6 Alum Sign .125"/St 12 Ga Ty III | |
| 710B013 | 80 | LF | Roadway Sign Post (W10 x 22 Steel Beam) | |
| 710B021 | 1190 | LF | Rdwy Sign Pt(#3 UCh GS or 2"14Ga SqTuSt) | |
| 726A000 | 11500 | LF | Port Concrete Safety Barriers Type 6 | |
| 726A001 | 60 | LF | Port Concrete Safety Barriers Type 6-A | |
| 726D020 | 6 | EACH | Portable Impact Atten Ass Uni Dir TL-2 | |
| 730A000 | 1 | LS | Removal Of Exist Traffic Control Unit (US-431 @ Sprague Avenue) | |
| 730C000 | 1 | LS | Furnish and Install Traffic Control Unit (US-431 & SR-901 @ Lindale Avenue) | |
| 730C001 | 1 | LS | Furnish and Install Traffic Control Unit (SR-21 @ Ramps A & C) | |
| 730C002 | 1 | LS | Furnish and Install Traffic Control Unit (SR-21 @ Ramps B & D) | |
| 730E000 | 12 | EACH | Metal Traffic Signal Pole Foundation | |
| 730G001 | 12 | EACH | Metal Traffic Signal Strain Pole | |
| 730H001 | 2350 | LF | Loop Wire | |
| 730I001 | 4280 | LF | Loop Detector Lead-In-Cable | |
| 730J010 | 9 | EACH | Vehicle Loop Detector | |
| 730K000 | 15 | EACH | Traffic Signal Junction Box | |
| 730L003 | 400 | LF | 1", Non-Metallic, Conduit | |
| 730L005 | 3490 | LF | 2", Non-Metallic, Conduit | |
| 730M017 | 1900 | LF | Intercon Cab Underground #14 AWG 20-1 | |
| 730N000 | 12 | EACH | Luminare Extension Assembly, 12 ft | |
| 730N010 | 4 | EACH | Luminaire Extension Assembly, 15 ft | |
| 730P022 | 14 | EACH | Vehicular Signal Head, 12 Inch, 3 Sect | |
| 730P024 | 6 | EACH | Vehicular Signal Head, 12 Inch, 5 Sect | |
| 730R022 | 3 | EACH | Controller Assembly, Type III, 8 Phase | |
| 730T000 | 3 | EACH | Wood Pole | |
| 730U015 | 1 | LS | Video Detection System | |
| 730U016 | 1 | LS | Video Detection System | |
| 730Y100 | 1 | LS | Furnishing And Installing Pedestal Pole | |
| 730Y101 | 1 | LS | Furnishing And Installing Pedestal Pole | |
| 740B000 | 1954 | SQFT | Construction Signs | |
| 740D000 | 650 | EACH | Channelizing Drums | |
| 740E000 | 100 | EACH | Cones (36" High) | |
| 740F002 | 38 | EACH | Barricades, Type III | |
| 740I002 | 19 | EACH | Warning Lights, Type B | |
| 740M001 | 100 | EACH | Ballast For Cone | |
| 741C010 | 2 | EACH | Port Seq Arrow & Chevron Sign Unit | |
| 742A001 | 2 | EACH | Portable Changeable Message Sign Type 2 | |
| 756A022 | 270 | LF | 4" Elect Conduit 1 Line Ty 5 Install | |
| 756A028 | 200 | LF | 6" Elect Conduit 1 Line Ty 5 Install | |
| 999 000 | 1760 | HOUR | Trainee Hours At 80 Cents Per Hour |